MAKE IT YOURS
Superior Transmitter Fibra.
Compact module for integrating third-party wired devices over Fibra

Standards and certifications
Superior Transmitter Fibra · TR.Y.F. Manufacturer-listed marks; regional and installation conditions apply.
A small board. A place in the whole system.
Superior Transmitter Fibra fits inside a third-party wired device and connects its contacts to an Ajax hub. The compact board adds named events, remote input settings and supervised Fibra communication. Two signal inputs support an alarm-and-tamper connection or two devices according to the wiring scheme, with a low-current supply for suitable sensors.
Key features. At a glance.
Any connection type
with NO, NC, EOL, 2EOL or 3EOL connection
Instant detection
of wired device connection loss
Installation inside the device enclosure




KeyArm feature
for integrated third-party device
Integration of roller shutter motion detector


Numerous event types
for the integrated device
Intrusion
Panic button
Fire
Fast connection to wired devices
by measurement of EOL resistors


Up to 2,000 m1
range of communication with an Ajax hub or a module that extends the Fibra line

Convenient wire connection
due to accessory 5-pin cable



Remote control and configuration
Informative in-app notifications
Chime
for shops, commercial and non-commercial facilities

Low power consumption

Power adjustment
- 1With U/UTP cat.5 cable. Range depends on cable type, topology and connected load. Check the wired system design with the Fibra power supply calculator before installation.
Ajax product information ↗ · Superior Transmitter Fibra specifications ↗
Fit Ajax integration inside the device.

A 40 × 15 × 12 mm board
Install the module inside the third-party device enclosure, with room for safe cable routing. Its supplied five-pin connection provides signal contacts and a low-current power output.
Make the message describe the real device.
Name the device, room and event
Select the appropriate event type for each connected device and give it a clear name and room. The configured type determines the notification and monitoring-station event code. A fire or leak event comes from the connected detector; the integration module does not detect that hazard itself.
Let the connected contact manage security.

KeyArm control
A supported wired control can arm or disarm selected security objects or activate Night Mode. Configure the allowed action and the tamper-related lockout in the app, then test both normal use and tamper behaviour.
KeyArm requires a compatible hub with OS Malevich 2.17 or later. Monitoring a blocking element or bolt lock requires 2.25 or later.
Give an event a clear location and meaning.

Named notifications and connected actions
The app identifies the connected device, event and room. Supported events can trigger configured actions on separate Ajax automation devices. Chime requires a compatible Ajax siren; this board contains neither a siren nor a power relay.
Match the sensor to the available supply.
Up to 50 mA for the wired device
Fibra powers the module over a 7–30 V DC operating range. Its single output supplies 10.5–15 V DC with a maximum total load of 50 mA. Check the sensor’s required voltage and current before choosing this connection.
One supervised wired connection.
Fibra communication
The four-wire connection carries data between the module and a compatible Ajax hub. Two-way communication, encryption with a dynamic key and device authentication help protect this connection. The module remains part of the hub’s system; it is not a standalone control panel.
Use the current compatibility list and supported firmware. The host’s device capacity and the line power budget still apply.
Plan the data path and cable limits.
Up to 2,000 m on the Fibra line
The stated Fibra reach assumes U/UTP cat.5 cable. It is separate from the shorter cable between the integration module and a third-party device. Check topology, signal strength, load and voltage at the final device; a ring has different limits.
Protection that also watches itself.

Detect changes in the wired connection
Supported EOL connections distinguish specified alarm and fault states, including short circuits or a broken wire. Wire the end-of-line resistors at the device and test each expected condition.

Supervise the connection to the hub
Regular polling lets the hub report a missing module. Event notifications identify the affected device and room so the fault can be investigated.
The 36-second example depends on a 12-second polling interval and three missed packets. Actual fault timing follows the hub settings.
Check the enclosure and tamper circuit
Test the third-party device’s configured tamper circuit. This board sits inside the connected device; protection depends on that enclosure and the chosen alarm/tamper wiring.
Plan additional electrical protection
A compatible LineProtect module can isolate a damaged section and protect devices between that module and the hub. It is a separate product and needs to be positioned as part of the line design.
Connect, configure and test the complete path.

Prepare the installation
An accredited Ajax partner checks compatibility, cable routes, power and tamper connections before fixing the equipment. Isolate the relevant power supplies before wiring. Fit the board inside the third-party enclosure and connect the supplied five-pin cable.
Find the right wired integration module.
Keep suitable wired detectors when moving to Ajax. Compare signal inputs, detector power and whether the module can also control equipment.
Compare wired integration →Every detail, in one place.
Communication
- Fibra communication technology
- Two-way wired transfer of alarms, events and commands, with device supervision and supported remote configuration.
- Line connection
- 4-core cable
- Connection
- to any point of the Fibra line Superior Transmitter Fibra can be installed after a hub, detector, keypad, or siren.
- Fibra line length
- up to 2,000 m When using the U/UTP cat.5 twisted pair cable.
- Encrypted communication
- Encrypted communication between the module and the compatible Ajax hub.
Wired devices connection
- Supported configurations
- roller shutter tamper wired device with 15 event types
- Connector pins
- 12V — power supply output for a wired detector GND — ground Z1–Z2 — inputs for connecting a wired detector COM — common input for connecting signal contacts of a wired detector Superior Transmitter Fibra has 2 inputs (Z1 and Z2) to connect the wired detector using the AATT (i.e., Alarm Alarm Tamper Tamper) scheme.
- Type of connection
- NO, NC, EOL, 2EOL, 3EOL With EOL total resistance from 1 kΩ to 40 kΩ with a 100 Ω increment.
- Cable length
- up to 3 m When using a signal cable with a 0.22 mm² copper conductor.
- Operation mode
- pulse, bistable
- Event types
- 15 configurable types: tamper; intrusion; fire; auxiliary; panic; gas; malfunction; leakage; glass break; high temperature; low temperature; masking; duress (opening); vibration (seismic); custom. Configured in Ajax apps by a PRO or administrator.
Sabotage protection
- Protection against spoofing
- device authentication
- Instant line damage detection
- Valid for EOL, 2EOL, or 3EOL connections.
- Communication loss detection
- after 36 s Between the hub and Superior Transmitter Fibra. It can be changed in the hub settings.
Power supply
- Module’s operating voltage range
- 7–30 V⎓, 185 mW (no load) / 1224 mW (with load) The hub powers the module.
- Module’s nominal operating voltage
- 24 V⎓
- Quiescent module’s current consumption at nominal voltage
- 2.1 mA
- Maximum module’s current consumption at nominal voltage
- 7.7 mA (no load) 51 mA (with load)
- Output to the connected wired device
- 10.5–15 V⎓, up to 50 mA (total maximum current consumption) One power supply line from Superior Transmitter Fibra.
Board
- Dimensions
- 40 × 15 × 12 mm
- Weight
- 6 g
- Operating temperature range
- from −25 °C to +50 °C
- Operating humidity
- up to 75%
- Electric shock protection
- Class II
What’s in the box
- Superior Transmitter Fibra
- Accessory 5-pin cable
- Quick start guide
For your installation
- Selected as part of an installer-reviewed security or automation project.
- Fibra needs a supported hybrid control panel, checked cable type and topology, termination and a complete power budget. Existing alarm cabling is not automatically suitable.
- Superior Transmitter Fibra should be installed inside the wired detector case. The module requires a space with the following minimum dimensions: 40 × 15 × 12 mm