MAKE IT YOURS
Superior DoorProtect Plus Fibra.
Wired reed-switch opening detector with shock and tilt sensors

Standards and certifications
Superior DoorProtect Plus Fibra · DP.P.F. Manufacturer-listed marks; regional and installation conditions apply.
Opening, impact and a change in angle.
Superior DoorProtect Plus Fibra adds shock and tilt detection to a wired opening sensor. It can respond to an attempt to force a door or move a window before the opening contact changes. Adjustable sensitivity and tilt timing help the installer match the detector to the actual frame, including a planned airing position. A compatible wired Ajax hub brings the events into the same app as the rest of the system.
Key features. At a glance.


Two reed switches
the magnet can be placed on the left or right side of the detector
Shock and tilt detection
with a built-in accelerometer


Adjustable sensitivity
for shock and tilt sensor


More installation options
with two magnets included

Chime feature1

Easy wiring
with removable device board


Informative push notifications

Power adjustment

Remote control and configuration
Up to 2,000 m2
communication range with an Ajax hub or a module that extends the Fibra line

Terminals to connect a third-party NC detector


Up to 147 mW
low power consumption
Two colours
of matte enclosure


- 1The Chime feature requires an Ajax siren to operate. Learn more about Chime.
- 2With U/UTP cat.5, 4 × 2 × 0.51 cable. Other cable types may have different values. Please use the Fibra power supply calculator to check the wired system project before installation.
Ajax product information ↗ · Superior DoorProtect Plus Fibra specifications ↗
Protection in real places.





Superior DoorProtect Plus Fibra
Every detail has a purpose.
Explore the function, installation and system requirements of Superior DoorProtect Plus Fibra.
Loading detail…
Know what changed at the entrance.

A magnet on either side
Two reed switches let the installer place one magnet to the left or right of the detector. When the protected door or window opens, the magnet moves away and the detector reports the change.
Use one magnet on one side only. Installing magnets on both sides can prevent correct opening detection.
Fit the detector to the real frame.
Choose one of the supplied magnets
Use the small magnet for a gap up to 1 cm or the large magnet for a gap up to 2 cm, following the manual’s mounting-plane and direction-specific limits. Check opening and closing at the final position.
Both magnets are included so the installer can choose the suitable one. They are not meant to be installed simultaneously.
Place the sensor where it can detect the event
Mount the detector on the moving door or window leaf when using shock or tilt detection, with the magnet on the frame.
Designed for indoor use: −10 to +40 °C and up to 75% humidity. Do not treat the enclosure as weatherproof.
Include a nearby wired contact.

Bring an additional contact into the system
The terminals accept a supported normally closed (NC) detector. Position it no more than 1 m from the DoorProtect unit, enable the external contact in the app and test the alarm path.
The DoorProtect terminals do not power the additional detector. Any power it requires must be supplied separately.
Hear an entrance while the system is disarmed.

Chime through an Ajax siren
A compatible Ajax siren can give a short sound when the door opens while the system is disarmed. Choose the sound and volume in the app, and use different patterns for different entrances.
Chime requires an Ajax siren, purchased separately. The opening detector does not contain a doorbell speaker.
A wired connection to the whole system.
Fibra carries power and events
A four-core Fibra cable connects the detector to a compatible wired Ajax hub. Two-way communication, encrypted data and device authentication help protect the connection. The detector has no camera and requires the hub to manage the system.
Up to 2,000 m on a beam with U/UTP cat.5 4 × 2 × 0.51 mm (24 AWG) copper cable, subject to the complete cable and load calculation. Check the selected hub, topology and firmware; a ring has different limits.
Include every device in the power plan.
Power and backup come from the wired system
The detector receives its supply through the Fibra cable. There is no replaceable detector battery; standby depends on the hub and any separately powered modules in the cable route.
Operating input: 5–30 V DC, with 24 V DC nominal. The current specification lists 147 mW maximum consumption.
Protection that also watches itself.

Know when the connection needs attention
Regular exchanges let the hub supervise the detector and report a lost connection. Device and room names help identify where the problem occurred.
Fault-detection time depends on the polling settings. A short-circuit warning is not the electrical-sabotage isolation provided by a separate LineProtect module.
Opening and removal alerts
Tamper switches report opening the enclosure and detaching the detector from its mounting surface. Secure the specified fixing points and holding screw, then test both events before handover.
Fit it, add it and test the actual opening.

Prepare the cable and mounting
A removable board and cable-routing openings give the installer access to the terminals. Plan the cable route and permitted magnet gap before fixing the detector, then use the supplied fasteners and holding screw.
Find the right opening detector.
Compare protection for doors and windows across Baseline, Superior and Fibra. See which events a detector can notice and how it fits your frame, wiring and everyday use.
Compare opening detectors →Every detail, in one place.
Communication
- Fibra communication technology
- Two-way system communication for the functions specified for this model.
- Line connection
- 4-core cable
- Fibra line length
- up to 2,000 meters When using the U/UTP cat.5 twisted pair.
Detection
- Sensing element
- 1 × accelerometer 2 × reed switch The magnet can be installed to the right or left side of the detector.
- Additional detector connection
- Wired detector with the normally closed (NC) contact type.
- Shock sensor sensitivity
- 3 levels Adjusted by PRO or user with admin rights in the Ajax app. The detection radius depends on the material type: Framed glass window — 1.2 m (high sensitivity level), 1 m (low sensitivity level). Wooden plate — 1.2 m (high sensitivity level), 1 m (low sensitivity level). Concrete plate — 0.75 m (high sensitivity level), 0.5 m (low sensitivity level). The smoother and cleaner the detection surface is, the better the detection radius is.
- Option to ignore single shock
- Enabled by PRO or user with admin rights in the Ajax app.
- Tilt sensor activation threshold
- from 5° to 25° Adjusted by PRO or user with admin rights in the Ajax app.
Anti-sabotage protection
- Tampering alarm
- Alerts of attempts to detach the detector from the surface or remove the mounting panel.
- Protection against forgery
- Device authentication
Power supply
- Detector’s operating voltage range
- 5−30 V⎓, up to 147 mW The detector is powered by the control panel.
- Detector’s nominal operating voltage
- 24 V⎓
- Quiescent detector’s current consumption at nominal voltage
- 0.043 mA
- Maximum detector’s current consumption at nominal voltage
- 6.1 mA
Enclosure
- Dimensions
- 90.5 × 21 × 18.5 mm
- Weight of the white device
- 17 g
- Weight of the black device
- 15 g
- Operating temperature range
- from −10 °C to +40 °C
- Operating humidity
- up to 75%
- Protection class
- IP50, IK04
What’s in the box
- Superior DoorProtect Plus Fibra
- Big magnet
- Small magnet
- Installation kit
- Quick start guide
For your installation
- Selected as part of an installer-reviewed security or automation project.
- Fibra needs a supported hybrid control panel, checked cable type and topology, termination and a complete power budget. Existing alarm cabling is not automatically suitable.
- Do not install the detector using both magnets at the same time.
- The detector recognizes only one magnet on one side of the detector — left or right.
- The device is designed for indoor use only.