Skip to main content
Including 21% VAT · delivery terms apply

MAKE IT YOURS

FireProtect 2 AC (Heat).

Wireless mains-powered fire detector with heat sensor

MAKE IT YOURS

Wireless mains-powered fire detector with heat sensor

€128.77Includes 21% VAT

Available from supplier

Residence

Choose smoke, heat, carbon monoxide or leak detection for the actual risks in each room.

Compare with another fire detector →
Colour. Black
Quantity. How many do you need?
1
Needs checking

Confirm the exact hub for FireProtect 2 AC (Heat) Jeweller; family names do not identify a supported pair.

What else needs checking?

The model's general minimum is OS Malevich 2.18; identify the exact hub because host-specific limits can be higher.

Confirm the regional equipment version for LV; a country name alone does not identify the radio version.

Sensors: heat. Requires 110–240 V AC, 50/60 Hz at each detector position. The backup battery does not replace its normal mains supply. Indoor use at 0°C to +50°C and up to 80% humidity. Confirm placement and alarm audibility separately; this is not an EN54 system selection.

Fallback fire interconnection. Requires compatible FireProtect 2 device firmware 5.59.2.XX or later, OS Malevich 2.19+ for hub configuration, and an enabled, tested peer network. Basic hub pairing does not confirm this feature.

Required for your setup
  • A supported control panel — confirm the exact version
Ajax compatibility reference

Saved together in your project. Choose support after your equipment.

Standards and certifications

FireProtect 2 AC (Heat) Jeweller · FP2.ACH.J. Manufacturer-listed marks; regional and installation conditions apply.

Mains-powered heat detection for the room.

FireProtect 2 AC (Heat) Jeweller monitors a high temperature or rapid rise using two thermistors. A built-in siren gives a local warning, while a compatible hub adds notifications and coordinated alarms. It uses mains power with a non-replaceable backup battery. Smoke and CO detection require separate suitable devices.

Key features. At a glance.

Two types of interconnected fire alarm1

Interconnected fire alarm

Primary: via an Ajax hub, an alarm in 20s

Heat sensor

Two thermistors

Two thermistorTwo thermistor

SmartBracket

with an adjustable rotation angle

Power supplyPower supply

Easy wiring

with WAGO 221

Easy writingEasy writing

Main power supply2

110–240 V~

Backup battery

Power supplyPower supply

85 dB built-in siren

Jeweller radio communication

Jeweller and Wings
Remote control

Remote control and configuration

Operates as part of the Ajax system or without pairing with an Ajax hub

Informative in-app notifications

10:00Ajax

Home: Rapid temperature rise detected, FireProtect 2 in Kitchen

10:00Ajax

Home: Photo by scenario taken, MotionCam (PhOD) in Kitchen

Two colours

Two coloursTwo colours

Up to 1,700 m3

range of communication with an Ajax hub

  1. 1Requires supported detector hardware/firmware, hub version, configuration and tested radio coverage. See the interconnection section for the applicable conditions.
  2. 2The backup battery is non-replaceable. Replace the detector when the backup battery is depleted or the 10-year service life ends.
  3. 3Range is measured in open space; walls and installation conditions reduce it.

Ajax product information ↗ · FireProtect 2 AC (Heat) Jeweller specifications ↗

Protection in real places.

FireProtect 2 AC (Heat) Jeweller installed in a kitchen
Kitchen
FireProtect 2 AC (Heat) Jeweller installed in a bedroom
Bedroom
FireProtect 2 AC (Heat) Jeweller installed in a home office
Home office
FireProtect 2 AC (Heat) Jeweller installed in a workshop
Workshop

Detect a high temperature or a sudden rise.

Two thermistors positioned outside the enclosure

Two A1R-class thermistors

Two thermistors monitor temperature outside the enclosure. The detector raises a heat alarm above +64 °C or when temperature rises by more than 10 °C within one minute.

These alarm conditions apply to the European model. Choose the sensor combination and installation position for the room; heat detection does not replace required smoke coverage.

Mains power. Backup when the supply stops.

Mains wiring, mounting and backup-power demonstration

110–240 V AC with a built-in reserve

The detector uses 110–240 V AC at 50/60 Hz, with mains consumption up to 2 W. A built-in CR-2/3AZ lithium battery provides backup when the external supply is interrupted. The app shows external-power and backup-battery status when a hub is connected.

The backup battery is non-replaceable. Replace the detector when that battery is depleted or at the end of its 10-year service life. Battery Life Optimization must be enabled; backup endurance depends on use and conditions.

A local alarm, with a clear device status.

Built-in siren and sound indication

85 dB sound and LED indications

The built-in siren is rated at 85 dB at 3 m. Sound patterns and LEDs distinguish an alarm from a fault, low battery or end of life. With a compatible connected hub, configured app notifications identify the detector and its room.

The detector monitors its own sensors even when the intrusion system is disarmed. As a standalone detector it provides local warnings; app notifications and remote settings require a hub.

One detector can warn the others.

Alarm passed to fire detectors through the hub

Primary alarm through the hub

An enabled detector sends its alarm to the compatible Ajax hub, which activates the other fire detectors within 20 seconds. System capacity depends on the hub, connected devices and configuration.

Alarm passed directly between fire detectors

A direct path between detectors

Compatible FireProtect 2 detectors can propagate the alarm directly within 60 seconds, including when the hub connection is lost. This fallback path runs alongside primary interconnection.

Requires supported detector hardware and firmware 5.59.2-series or later, the enabled fallback setting and a successful coverage test. With a hub, use OS Malevich 2.19 or later; Hub (4G) requires 2.28 or later.

A local network without a hub

Supported detectors can be paired into a standalone alarm network of up to 50 units. Follow the exact pairing instructions and test coverage. This arrangement provides local sound and LED warnings; it does not send Ajax app notifications without a hub.

Keep the radio path connected.

Jeweller two-way communication

Jeweller carries alarms and device states using encrypted communication, device authentication, frequency hopping and automatic power adjustment. Check the model’s specified open-space range and measure signal strength in its installed position.

Check the hub before installation.

Exact model and firmware matter

These AC detectors require a supported Ajax hub with OS Malevich 2.18 or later. Hub (4G) requires 2.28 or later. Fallback interconnection has the additional conditions described above. Confirm the radio region and exact compatibility list before pairing.

See the alarm and its source.

Ajax event log showing a temperature alarm

Device, room and event history

With a connected hub, Ajax app notifications identify the detector and room. The event log records the time and event type. Configured PRO Desktop or monitoring-station integration adds an operator view; monitoring service and response arrangements are separate.

Add context to an alarm.

FireProtect 2 AC triggering a scenario with a separate MotionCam (PhOD)

Photos from a separate detector

A compatible MotionCam (PhOD) can take photos after a configured FireProtect 2 alarm. A suitable hub, photo permissions and the scenario must be set up beforehand. FireProtect 2 AC has no built-in camera.

Separate automation devices can support a professionally planned response involving suitable circuits or door hardware. Scenarios do not replace the required alarm response.

A neat route for surface wiring.

CableTrunk joining surface trunking to the detector mounting panel

CableTrunk, where the cable comes from the side

The optional CableTrunk accessory joins surface cable trunking to FireProtect 2 AC. It provides a dedicated route to the mounting panel while keeping the ceiling finish tidy.

CableTrunk is a separate accessory. Electrical work and cable routing must be included in the installation plan.

Wire, pair and check the installation.

SmartBracket with WAGO 221 connectors

A qualified installer connects the mains supply using the two pre-installed WAGO 221 terminals in SmartBracket, fixes the panel and aligns the detector. Choose the mounting position and clearances from this model’s manual.

Indoor use only: 0 to +50 °C and up to 80% humidity. Electrical work is planned and quoted separately. A room photograph is an application example, not a placement rule.

Test it. Respond to service warnings.

Using the front panel to test the detector

Test/Mute on the front panel

Press the centre of the front panel to start the detector self-test as described in the manual. App testing is available with a connected compatible hub. Check the sound and light indications after commissioning and follow the regular testing schedule.

Wait at least 3 minutes after switching the detector on before testing. Local requirements may call for more frequent checks.

Plan for the detector’s service life

Respond to fault, low backup-battery and end-of-life warnings. The detector has a 10-year service life and must also be replaced if its non-replaceable backup battery is depleted. Do not treat a renewed mains connection as a battery replacement.

Manufacturer’s product information

Find the right fire detector.

Compare what each FireProtect detects, how it is powered and what you will need to maintain. Choose the sensor combination for the hazards in the room.

Compare fire detectors →

Every detail, in one place.

Communication
Jeweller communication technology
Two-way system communication for the functions specified for this model.
Radio signal range
up to 1,700 m Between the detector and a hub (or radio signal range extender) in an open space.
Encrypted communication
Encrypted device communication.
Frequency hopping
Radio communication uses frequency hopping to prevent interception and jamming.
Dangerous temperature detection
Sensitive element
according to the requirements for Class A1R heat detectors Requirements of EN 54-5 and BS 5446-2 standards.
High temperature alarm
at temperatures above 64 °C
Temperature spike alarm
when the temperature rises more than 10 °C in 1 minute or less
Additional features
In-built siren
volume 85 dB at a distance of 3 meters Sound notification of alarms. Active until the reason for triggering is eliminated or until the user disables notification.
Interconnected Fire Detectors Alarms
via primary interconnection If one of the fire detectors in the system detects a threat, it sends an alarm to the hub. Within 20 seconds, the hub initiates an interconnected alarm and sends data to Ajax apps. via fallback interconnection At the same time with notifying the hub, the initiating detector sends an alarm directly to other detectors. All connected detectors activate the buzzer within a minute. It will work even in the worst-case scenario of losing connection with the hub.
LED indication
green is a power indication An LED indicator on the device enclosure lights continuously when powered by an external power source. If the device draws power from the backup battery, the LED indicator lights up once every 56 seconds. This indication complies with the requirements stipulated in EN 14604 and EN 50291 standards. yellow is a malfunction indication An LED indicator on the device enclosure lights up to signal detected malfunctions. This can occur in instances such as battery depletion. red is a fire alarm indication An LED indicator on the device enclosure lights up when the detector registers a fire alarm.
Button on the front panel of the detector
In normal mode, pressing the button initiates the detector test. In the event of an alarm or malfunction, pressing it turns off the device sound notification.
External power supply
110–240 V~, 50/60 Hz The phase and neutral cables from the external power supply should be connected to the WAGO terminals on SmartBracket mounting panel. To remove the detector from SmartBracket, there is no need to disconnect the power cables.
Sabotage protection
Tampering alarm
Notifications on attempts to detach the detector from the surface or remove it from the mounting panel.
Protection against spoofing
device authentication
Communication loss detection
within 15 minutes The time required to detect a communication loss depends on the settings for the number of undelivered data packages (specified in the Jeweller or Jeweller/Fibra settings).
Power supply
Main
110–240 V~, 50/60 Hz Up to 2 W of mains power consumption.
Backup
1 non-replaceable lithium battery CR-2/3AZ Allows the detector to operate autonomously without the main power source.
Enclosure
Dimensions
122 × 122 × 54 mm
Weight
303 g
Operating temperature range
from 0 °С to +50 °С
Operating humidity
up to 80%
What’s in the box
  • FireProtect 2 AC (Heat) Jeweller
  • SmartBracket mounting panel
  • WAGO 221 3-conductor terminal — 2 pcs.
  • (pre-installed in SmartBracket)
  • Installation kit
  • Quick start guide
For your installation
  • Confirm the supported control panel, device software and regional radio version; test coverage at the final installation position.
  • The device is designed for indoor installation only.; SmartBracket mounting panel allows adjusting the position of the detector even after installation.

Optional additions

Find the right protection.

Service benefits & conditions

Eligibility, availability and service terms are confirmed with your quote.

  1. Included installation. Applies to eligible wireless equipment purchases with an agreed total from €6,000 including VAT. The proposal confirms the installation scope and local coverage. Configuration, agreed wireless installation, oversight, tests and training are included. Electrical and plumbing work and monitoring subscriptions are separate. G3 and Superior wireless S-line products do not count towards the €6,000 eligible equipment budget and are not covered by the included-installation offer. Their installation is quoted separately. Fibra and cabling are also quoted separately. Only eligible battery-powered wireless devices, ordinary hubs, ReX and wireless kits contribute. Devices requiring additional power or wired connections (including Relay, WallSwitch, LightSwitch, Socket, Outlet, FireProtect 2 AC and integration modules), WaterStop, Hub BP, video and EN54/Type4 equipment do not count. Accessories, delivery and Care fees do not count either. Hub and ReX connection to an existing socket is included; new power supplies, cabling, electrical and plumbing work are arranged separately. Included installation is available at one property in Latvia, Lithuania or Estonia and includes preparation and the visit. Below €6,000 of eligible equipment, it is a paid option at checkout. Your basket shows the complete service price, including VAT; scope and the visit date are agreed before installation.
  2. Free EU delivery. Free equipment delivery within the EU. Stock, dispatch and destination service are confirmed before accepting your order. Where a three-business-day delivery service is confirmed, it runs from dispatch. Split shipments and made-to-order products may follow separate agreed schedules. Delivery agreed as free does not acquire an undisclosed surcharge. Installation is scheduled separately.
  3. Payments, finance and leasing. Monthly payments and leasing with an upgrade option require a separate agreement, subject to finance-provider approval, credit eligibility and country availability. The provider, deposit, APR, fees, total payable, duration, ownership and return or upgrade conditions are explained before any agreement. An enquiry or saved preference does not activate credit.
  4. Personal setup. One scheduled remote first-setup session for eligible equipment purchased from SAFE365. Equipment must be ready for configuration. Session scope, language and availability are confirmed when booked; physical installation and cabling are separate unless included in your project.
  5. Care 24. Included remote support and agreed remote maintenance for the first 24 months for eligible SAFE365 purchases. The start date, support hours, access permissions and covered tasks are confirmed with your order. On-site work, 24/7 alarm monitoring and extended hardware cover are not included unless separately agreed. Statutory rights and the manufacturer's applicable warranty are unaffected.
  6. Local installation. Partner coverage varies by country and postcode. A named partner, the work scope, responsibility and price are confirmed in writing before commitment. Local installation is included only for an eligible agreed package; otherwise it is quoted separately.
  7. Included system preparation. Preparation is included from €3,000 of eligible equipment, including VAT after discounts. The order must include an eligible hub. We configure, label and check the marked wireless devices and provide individual instructions. Below the threshold, preparation is a paid option at checkout; your basket calculates the price. The same equipment eligibility rules as for included installation apply. Service charges do not count towards either threshold.

GOLDNBEE SIA — SAFE365 operator for the Baltics and Northern Europe · Reg. 40103558050 · VAT LV40103558050 · Jaunā Mežaparka iela 36-2, Rīga, LV-1014, Latvia

SAFE365. Ajax equipment, thoughtfully brought together.

Product information and photography on this site come from Ajax Systems. Ajax is a trademark of its owner.

Prices include standard consumer VAT for the selected country. Special tax territories, business orders, delivery, service terms and availability are confirmed with your proposal.

Loading page and saved details…