EN54 FireProtect Jeweller detectors.
Wireless addressable point detectors

Standards and certifications
* Ajax shows these marks for the EN54 FireProtect Jeweller detectors range. Check the linked documentation for the exact version and market.
IP21C applies to Heat/Sounder and Smoke/Sounder. Smoke, Heat and Heat/Smoke are IP20. All five are for indoor use.
Detect the risk. Identify the location.
EN54 FireProtect Jeweller detectors bring smoke and heat detection into an addressable wireless fire system. Five versions offer smoke, heat or combined sensing, with a built-in alarm sounder on the two Sounder models. Device, room and fire-zone information helps the responsible team locate an event, while replaceable batteries simplify ongoing service.
Key features. At a glance.
Compliance1
full compliance with the fire detection and alarm system standard
Device addressability
for informative notifications, effective management, and maintenance


Connection and configuration
via intuitive Ajax apps

Heat detection2
with selectable heat sensor mode in the app: A1, A1R, A1S, B, BR, BS, C, CR, CS, or a fixed temperature
Built-in Jeweller communication3
with the control and indicating equipment or range extender up to 1,700 m
Audible alarms4
On Heat/Sounder and Smoke/Sounder only · 32 selectable tones

Fast installation
5 min per device without enclosure disassembly


Up to 5 years6
on pre-installed CR123A batteries


Tool-free battery replacement
without enclosure disassembly


Solo 332 compatible7
Smoke test without the need to reach the detector
Dismantling protection
with SmartBracket locking
Informative push notifications
Tamper alarm
to alert when the device is detached or its enclosure is damaged
Two colors
of classy design to fit any interior


- 1Manufacturer-listed marks for this product range. Exact-model certification and regional conditions are shown above.
- 2Heat and Heat/Sounder: EN54-compliant modes A1R, A1S, BR, BS, CR and CS. Heat/Smoke: A1R, A1S, BR and BS only; no C-class or fixed-temperature mode. Smoke-only versions have no heat sensor.
- 3In open space.
- 4Sound pressure depends on the selected tone and model; see minimum and maximum levels measured at 1 m in the exact specifications.
- 5Smoke sensing is included in Smoke, Smoke/Sounder and Heat/Smoke only.
- 6Up to 5 years for Sounder models and 6 years for Smoke, Heat and Heat/Smoke, according to the exact specifications. Actual battery life depends on use and conditions.
- 7For testing smoke-equipped models in the appropriate test mode; aerosol does not test a heat-only sensor.
Overview of this product range. Features and ratings can differ by version. Ajax product information ↗ · EN54 FireProtect (Heat/Sounder) Jeweller specifications ↗
Protection in real places.








EN54 FireProtect Jeweller detectors
Every detail has a purpose.
Explore the function, installation and system requirements of EN54 FireProtect Jeweller detectors.
Loading detail…
Choose the detection your site needs.
Five versions. Specific functions.
Choose Smoke or Heat for one sensing type, Heat/Smoke for both, or Smoke/Sounder and Heat/Sounder to include an alarm sounder.
All five are addressable devices for a compatible EN54 fire system. None detects carbon monoxide. Heat/Smoke does not include a sounder. The family overview shows all capabilities; the selector and specifications identify the exact version.
Recognise the signs of fire.

For smoke-equipped versions
A dual-spectrum optical sensor uses blue and infrared light to assess particles inside the patented smoke chamber. HazeFlow 2 evaluates the signal to help distinguish smoke from common interference.
Applies to Smoke, Smoke/Sounder and Heat/Smoke. The chamber resists dust and insects; placement and testing still follow the selected model’s manual.
Set the right heat response.
Mode follows the model and location
Heat and Heat/Sounder offer A1, A1R, A1S, B, BR, BS, C, CR, CS and a fixed-temperature mode. Heat/Smoke offers A1, A1R, A1S, B, BR and BS only.
For EN54-compliant operation use A1R, A1S, BR or BS; Heat and Heat/Sounder additionally support CR and CS. Fixed-temperature mode is not EN 54-5 compliant. The rated ambient operating range remains 0 to +50 °C.
Two sensors. A choice of response.
Only on Heat/Smoke
The combined model can use its heat and smoke sensors together or independently. The default combined mode adjusts the secondary sensor’s sensitivity as the primary sensor detects developing signs of fire.
- Combined detection: one sensor is primary and the second helps confirm the event.
- Heat and smoke: either sensor can trigger the alarm independently.
- Heat only: the optical smoke sensor is not used for detection.
- Smoke only: the heat sensor is not used for detection.
Select the detection strategy in the system design. Coincidence detection between separate detectors is a different, system-level function.
Include audible warning where it is specified.
Sounder versions only
Smoke/Sounder and Heat/Sounder include 32 selectable tones. Sounders connected to the same control panel synchronise their audible alarms. Run the alarm annunciation test to verify audibility in the actual premises.
Sound pressure depends on the selected tone and model; see the minimum and maximum levels measured at 1 m in the exact specifications. Smoke, Heat and Heat/Smoke require separately specified alarm sounders and VADs.
A supervised link to the fire panel.
Jeweller, built in
Two-way Jeweller radio carries commands, alarms and device states to the compatible fire panel. Encryption, authentication and frequency hopping protect the link without a separate radio module.
Up to 1,700 m is an open-space figure. Walls and the installation layout reduce usable range. EN54 Fire ReX can extend the route; survey each link at its final position. Alarm delivery and connection-loss timing depend on the system and its settings.
Replace the batteries. Keep the detector.

Two replaceable CR123A batteries
Both batteries are pre-installed. Battery covers allow replacement without opening the detector enclosure; low-battery notifications help plan the service visit.
Up to five years for Sounder versions and up to six years for Smoke, Heat and Heat/Smoke, according to the exact specifications. Battery life depends on polling, alarms and operating conditions. Replace both batteries when notified and retest.
Know which device needs attention.

Remote device states
The panel supervises communication, batteries, tamper and the sensors present in the selected detector. Events identify the device, room, fire zone and configured location.
A 36-second default polling interval is not a guaranteed fault-notification time. Check the commissioned Jeweller settings and notification routes.
Test the complete response.

A smoke test for smoke sensors
Smoke-equipped versions support suitable test aerosols and Solo 332 equipment in the system’s Zone test mode. Test outputs can include the chosen sounders, visual alarms, indicators and relays.
A smoke aerosol does not test a heat-only detector. Follow the exact model’s test procedure and the site’s maintenance plan. Do not remove the smoke chamber lid during routine installation.
Mount, assign and commission.

Add the exact device
Scan the QR code in an Ajax app, then assign a room, fire zone and clear location name. Use EN54 Fire Hub and the supported regional radio version.
These devices belong to the fire control system; they are not standalone domestic smoke alarms or accessories for an ordinary intrusion hub.
Find the right fire device.
Compare EN54 detectors, EN54 and Type4 sounders and visual alarms, and EN54 Indicator. See what detects a fire, what warns people and what helps locate the alarm.
Compare fire detection and alarms →Every detail, in one place.
Communication
- Jeweller communication technology
- Two-way system communication for the functions specified for this model.
- Radio communication range
- up to 1,700 m Between the device and control and indicating equipment (CIE) or a range extender in an open space.
- Encrypted communication
- Encrypted device communication.
- Frequency hopping
- To prevent radio interference and jamming.
Dangerous temperature detection
- Sensitive element
- 2 × thermistor According to the EN 54-5 requirements for heat detectors of Class A1, B, and C with rate-of-rise (R) and static (S) response types.
- Heat sensor modes
- A1, A1R, A1S; B, BR, BS; C, CR, CS; Fixed temperature For better detection of fire hazards, depending on the installation site of the device. Can be selected in the device settings. Only the following heat sensor modes are compliant with EN 54 requirements: A1R, A1S, BR, BS, CR, and CS.
Alarm annunciation
- Alarm type
- acoustic
- Sound volume
- At a distance of 1 m Tone 1: 970 Hz — min 66, max 82 dB; Tone 2: 800 Hz / 970 Hz @ 2 Hz — min 66, max 86 dB; Tone 3: 800–970 Hz @ 1 Hz — min 73, max 89 dB; Tone 6: 554 Hz, 0.1 s / 440 Hz, 0.4 s — min 69, max 87 dB; Tone 7: 500–1200 Hz, 3.5 s / 0.5 s OFF — min 80, max 87 dB; Tone 13: 1200–500 Hz @ 1 Hz — min 75, max 86 dB Adjusted by a PRO or user with admin rights in an Ajax app.
- Sound pattern
- 32 tones
- Sound synchronization
- An audible alarm is automatically synchronized on all devices with a sounder connected to the same CIE.
- Alarm annunciation test
- An audible alarm check to ensure the fire alarm is clearly audible on the premises.
Sabotage protection
- Tamper button
- Fault notification when an attempt is made to remove the device from the mounting panel.
- Lock for SmartBracket
- to secure the device on the SmartBracket mounting panel When locked, the lock secures the device and prevents it from being removed without a special tool.
- Protection against spoofing
- device authentication
- Connection loss detection
- after 36 s Detection time depends on Jeweller settings.
Power supply
- Battery
- 2 × CR123A Pre-installed.
- Tool-free battery replacement
- To replace the batteries, open the lids of the battery compartments.
- Reverse polarity protection
- Prevents device damage if the batteries are put in incorrectly.
- Recommended battery type
- Huiderui CR123A; 3 V; 1,600 mAh, LiMnO₂
- Calculated battery life
- up to 5 years
Enclosure
- Dimensions
- 124 × 124 × 48 mm
- Weight
- 278 g
- Operating temperature range
- from 0 °C to +50 °C
- Operating humidity
- up to 80%
- Protection class
- IP21C
- Flammability rating
- UL 94 V-0
Revision
- Revision
- 3
What’s in the box
- EN54 FireProtect (Heat/Sounder) Jeweller
- SmartBracket mounting panel
- 2 × CR123A battery (pre-installed)
- Installation kit
- Quick start guide
For your installation
- Selected as part of an installer-reviewed EN54 fire design.
- Confirm the supported control panel, device software and regional radio version; test coverage at the final installation position.
- The device is designed for indoor use only.
- The SmartBracket mounting panel allows the detector to be rotated up to 90° even after installation.
- Choose the exact version: sensing, power, casing, pack size or interface details can differ between the listed models.