Skip to main content
Including 21% VAT · delivery terms apply

MAKE IT YOURS

Superior DoorProtect G3 Fibra.

Wired reed-switch opening detector with shock, tilt, and masking sensors

MAKE IT YOURS

Wired reed-switch opening detector with shock, tilt, and masking sensors

€85.63Includes 21% VAT

Available from supplier

Superior · G3

Equipment for a professionally designed Grade 3 system. The complete system, firmware and installation determine its achievable grade.

Separate installation quote. This model does not count towards the €6,000 installation offer.¹

Explore related models

Each is a separate model. Compare its features, hub compatibility and installation before choosing.

G3 and Superior wireless S-line products do not count towards the €6,000 eligible equipment budget and are not covered by the included-installation offer. Their installation is quoted separately. Fibra and cabling are also quoted separately. Only eligible battery-powered wireless devices, ordinary hubs, ReX and wireless kits contribute. Devices requiring additional power or wired connections (including Relay, WallSwitch, LightSwitch, Socket, Outlet, FireProtect 2 AC and integration modules), WaterStop, Hub BP, video and EN54/Type4 equipment do not count. Accessories, delivery and Care fees do not count either. Hub and ReX connection to an existing socket is included; new power supplies, cabling, electrical and plumbing work are arranged separately.

Compare with another opening detector →
What to know about Fibra

Wireless is a practical choice when you want to avoid running detector cables. Fibra suits a planned wired installation or suitable existing cabling, after a professional assessment.

An accredited Ajax partner designs and commissions the wired system. We check cable routes, line power and the exact hub with your complete equipment list.

Wireless and Fibra can share a compatible hybrid hub. The selected device and firmware must also be supported. Cabling and installation are quoted separately.

Fibra models use the official Superior product-line name.

Ajax Fibra guidance
Colour. Black
Quantity. How many do you need?
1
Project review

Confirm the compatible Fibra hub, cable topology, termination and complete line power budget.

What else needs checking?

Confirm the installed hub and device software for the functions you need.

Confirm the regional equipment version for LV and local wired-installation requirements.

Selected as part of an installer-reviewed security or automation project.

Required for your setup
  • A supported control panel — confirm the exact version
Ajax compatibility reference

Saved together in your project. Choose support after your equipment.

Standards and certifications

Superior DoorProtect G3 Fibra · DP.G3.F. Manufacturer-listed marks; regional and installation conditions apply.

See Ajax for the certified model and installation conditions.

Watch the opening. Check the magnetic field.

Superior DoorProtect G3 Fibra combines opening, shock and tilt detection with a sensor that recognises attempts to substitute the normal magnetic field. Its magnetometer is calibrated at the installation site, while two tampers supervise the enclosure and mounting. The G3 design suits installations with higher security requirements, but correct placement, calibration and the capabilities of the complete system remain essential.

Key features. At a glance.

Two reed switchesTwo reed switches

Two reed switches

the magnet can be placed on the left or right side of the detector

Protection against chattering

to prevent false alarms

Shock and tilt detection

with a built-in accelerometer

Shock and tilt detectionShock and tilt detection
Adaptable to any objectAdaptable to any object

Adaptable to any facility

adjustable magnetometer, shock and tilt sensors

Protection against magnet spoofing

with a built-in magnetometer

180° rotation

of the front panel is possible during installation

180° rotation

Chime feature1

Chime feature
Terminals to connect a third-party NC detectorTerminals to connect a third-party NC detector

Terminals to connect a third-party NC detector

No impact from metal surfacesNo impact from metal surfaces

No impact from metal surfaces

on the magnet and reed switches, thanks to plastic spacers

Easy wiring

with removable device board

Easy wiringEasy wiring
Remote control and configuration

Remote control and configuration

Informative push notifications

nowAjax

Office: opening detected, Superior DoorProtect G3 Fibra in Hall No. 1

nowAjax

Production: shock detected by Superior DoorProtect G3 Fibra in Workshop No. 1

Fibra wired communication

Fibra wired communication

Power adjustment

low power consumption

Up to 20 mW

Up to 2,000 m2

communication range with an Ajax hub or a module that extends the Fibra line

Two colors

of matte enclosure

Two coloursTwo colours
  1. 1The Chime feature requires an Ajax siren to operate. Learn more about Chime.
  2. 2With U/UTP cat.5 4×2×0.51 mm (24 AWG) cable. Other cable types may have different values. Use the Fibra power supply calculator to check the system project.

Ajax product information ↗ · Superior DoorProtect G3 Fibra specifications ↗

Protection in real places.

Bank
Bank
Museum
Museum
Medical lab
Medical lab
Safe
Safe

Superior DoorProtect G3 Fibra

Every detail has a purpose.

Explore the function, installation and system requirements of Superior DoorProtect G3 Fibra.

Loading detail…

Know what changed at the entrance.

High-end reed switches for reliable opening detection

A magnet on either side

Two reed switches let the installer place one magnet to the left or right of the detector. When the protected door or window opens, the magnet moves away and the detector reports the change.

Use one magnet on one side only. Installing magnets on both sides can prevent correct opening detection.

Detect an attempt to replace the magnet.

Magnetometer prevents sabotage

Calibrate the magnetic field at the site

The magnetometer compares the surrounding field with its calibrated reference and reports a masking attempt. Calibrate with the opening closed after installation and again after moving the detector.

Opening detection must be enabled. OS Malevich 2.19 or later allows the installer to choose detection always or only while armed. Check the required security configuration before changing this setting.

Match sensitivity to the opening

Test normal opening and closing as well as the masking response. The manual advises against High masking sensitivity near a door closer. Sliding arrangements can need a different setup if the magnet passes along the detector for an extended time.

Do not disable magnetic masking and still treat the installation as providing that protection. A Grade 3 detector alone does not establish the grade of the complete system.

Fit the detector to the real frame.

Metal frames and safes

Use the supplied spacers when mounting on a metal surface and keep the closed-position gap between detector and magnet at 5 mm or less. Check the manual’s direction-specific movement distances and verify every opening.

Keep the detector more than 1 cm from a third-party electromagnet, such as one in a door closer.

Wooden or plastic frames

On a non-metallic surface, keep the gap at 1 cm or less; spacers are optional. The enclosure’s front panel can be rotated 180° during installation to suit cable routing.

One magnet and two spacers are included. Test after final fixing and recalibrate the masking sensor if the installation position changes.

Include a nearby wired contact.

Enhanced security with additional detectors

Bring an additional contact into the system

The terminals accept a supported normally closed (NC) detector. Position it no more than 1 m from the DoorProtect unit, enable the external contact in the app and test the alarm path.

The DoorProtect terminals do not power the additional detector. Any power it requires must be supplied separately.

Hear an entrance while the system is disarmed.

Use a detector as a doorbell

Chime through an Ajax siren

A compatible Ajax siren can give a short sound when the door opens while the system is disarmed. Choose the sound and volume in the app, and use different patterns for different entrances.

Chime requires an Ajax siren, purchased separately. The opening detector does not contain a doorbell speaker.

A wired connection to the whole system.

Fibra carries power and events

A four-core Fibra cable connects the detector to a compatible wired Ajax hub. Two-way communication, encrypted data and device authentication help protect the connection. The detector has no camera and requires the hub to manage the system.

Up to 2,000 m on a beam with U/UTP cat.5 4 × 2 × 0.51 mm (24 AWG) copper cable, subject to the complete cable and load calculation. Check the selected hub, topology and firmware; a ring has different limits.

Include every device in the power plan.

Power and backup come from the wired system

The detector receives its supply through the Fibra cable. There is no replaceable detector battery; standby depends on the hub and any separately powered modules in the cable route.

Operating input: 5–30 V DC, with 24 V DC nominal. Use the current Ajax power calculator to size the complete line, including its cable losses and other connected devices.

Protection that also watches itself.

Regular polling

Know when the connection needs attention

Regular exchanges let the hub supervise the detector and report a lost connection. Device and room names help identify where the problem occurred.

Fault-detection time depends on the polling settings. A short-circuit warning is not the electrical-sabotage isolation provided by a separate LineProtect module.

Opening and removal alerts

Tamper switches report opening the enclosure and detaching the detector from its mounting surface. Secure the specified fixing points and holding screw, then test both events before handover.

Fit it, add it and test the actual opening.

Installation

Prepare the cable and mounting

A removable board and cable-routing openings give the installer access to the terminals. Plan the cable route and permitted magnet gap before fixing the detector, then use the supplied fasteners and holding screw.

Manufacturer’s product information

Find the right opening detector.

Compare protection for doors and windows across Baseline, Superior and Fibra. See which events a detector can notice and how it fits your frame, wiring and everyday use.

Compare opening detectors →

Every detail, in one place.

Communication
Fibra communication technology
Two-way system communication for the functions specified for this model.
Line connection
4-core cable
Fibra line length
up to 2,000 meters When using the U/UTP cat.5 twisted pair cable.
Detection
Sensitive elements
1 accelerometer 1 magnetic masking sensor 2 reed switches
Protection against reed switch chattering
The detector ignores vibrations lasting up to 0.15 s. Reed switches The magnet can be installed to the left or right side of the detector.
Input to connect an additional detector
Wired detector with the normally closed (NC) contact type. Additional detector connection
Shock sensor sensitivity
3 levels Adjusted by a PRO or a user with admin rights in the Ajax app. The detection radius depends on the material type: Framed glass window — 1.2 m (high sensitivity level), 1 m (low sensitivity level). Wooden plate — 1.2 m (high sensitivity level), 1 m (low sensitivity level). Concrete plate — 0.75 m (high sensitivity level), 0.5 m (low sensitivity level). The smoother and cleaner the detection surface is, the better the detection radius is.
Option to ignore single impact
Adjusted by a PRO or a user with admin rights in the Ajax app.
Tilt sensor activation threshold
from 5° to 25° Adjusted by a PRO or a user with admin rights in the Ajax app. Tilt and shock sensitivity
Spacers
2 pcs. Are needed to install the detector or the magnet on a metal surface, as they help to reduce the distance between the detector and the magnet. You can use one or two spacers at once.
Chime
When the system is disarmed, the siren makes a special sound to notify that the opening detectors are triggered.
Sabotage protection
Tamper alarm
2 tampers Notifications on attempts to detach the detector from the surface or open the front lid.
Magnetic masking sensor
The device detects an attempt to mask the main magnet of Superior DoorProtect G3 Fibra with a fraudulent magnet.
Holding screw
to secure the detector on the mounting panel
Protection against spoofing
device authentication
Power supply
Detector’s operating voltage range
5−30 V⎓ The detector is powered by the hub.
Detector’s nominal operating voltage
24 V⎓
Quiescent detector’s current consumption at nominal voltage
120 μA
Enclosure
Detector dimensions
102 × 21 × 19.5 mm
Magnet dimensions
102 × 21 × 19.5 mm
Weight of the white device
68 g
Weight of the black device
60.7 g
Operating temperature range
from −10 °C to +40 °C
Operating humidity
up to 75%
Protection class
IP30, IK04
What’s in the box
  • Superior DoorProtect G3 Fibra
  • Magnet
  • Spacers — 2 pcs.
  • Installation kit
  • Quick start guide
For your installation
  • Selected as part of an installer-reviewed security or automation project.
  • Fibra needs a supported hybrid control panel, checked cable type and topology, termination and a complete power budget. Existing alarm cabling is not automatically suitable.
  • Do not install the detector using both magnets at the same time. The detector recognizes only one magnet on one side of the detector — left or right. The device is designed for indoor use only.

Find the right protection.

Service benefits & conditions

Eligibility, availability and service terms are confirmed with your quote.

  1. Included installation. Applies to eligible wireless equipment purchases with an agreed total from €6,000 including VAT. The proposal confirms the installation scope and local coverage. Configuration, agreed wireless installation, oversight, tests and training are included. Electrical and plumbing work and monitoring subscriptions are separate. G3 and Superior wireless S-line products do not count towards the €6,000 eligible equipment budget and are not covered by the included-installation offer. Their installation is quoted separately. Fibra and cabling are also quoted separately. Only eligible battery-powered wireless devices, ordinary hubs, ReX and wireless kits contribute. Devices requiring additional power or wired connections (including Relay, WallSwitch, LightSwitch, Socket, Outlet, FireProtect 2 AC and integration modules), WaterStop, Hub BP, video and EN54/Type4 equipment do not count. Accessories, delivery and Care fees do not count either. Hub and ReX connection to an existing socket is included; new power supplies, cabling, electrical and plumbing work are arranged separately. Included installation is available at one property in Latvia, Lithuania or Estonia and includes preparation and the visit. Below €6,000 of eligible equipment, it is a paid option at checkout. Your basket shows the complete service price, including VAT; scope and the visit date are agreed before installation.
  2. Free EU delivery. Free equipment delivery within the EU. Stock, dispatch and destination service are confirmed before accepting your order. Where a three-business-day delivery service is confirmed, it runs from dispatch. Split shipments and made-to-order products may follow separate agreed schedules. Delivery agreed as free does not acquire an undisclosed surcharge. Installation is scheduled separately.
  3. Payments, finance and leasing. Monthly payments and leasing with an upgrade option require a separate agreement, subject to finance-provider approval, credit eligibility and country availability. The provider, deposit, APR, fees, total payable, duration, ownership and return or upgrade conditions are explained before any agreement. An enquiry or saved preference does not activate credit.
  4. Personal setup. One scheduled remote first-setup session for eligible equipment purchased from SAFE365. Equipment must be ready for configuration. Session scope, language and availability are confirmed when booked; physical installation and cabling are separate unless included in your project.
  5. Care 24. Included remote support and agreed remote maintenance for the first 24 months for eligible SAFE365 purchases. The start date, support hours, access permissions and covered tasks are confirmed with your order. On-site work, 24/7 alarm monitoring and extended hardware cover are not included unless separately agreed. Statutory rights and the manufacturer's applicable warranty are unaffected.
  6. Local installation. Partner coverage varies by country and postcode. A named partner, the work scope, responsibility and price are confirmed in writing before commitment. Local installation is included only for an eligible agreed package; otherwise it is quoted separately.
  7. Included system preparation. Preparation is included from €3,000 of eligible equipment, including VAT after discounts. The order must include an eligible hub. We configure, label and check the marked wireless devices and provide individual instructions. Below the threshold, preparation is a paid option at checkout; your basket calculates the price. The same equipment eligibility rules as for included installation apply. Service charges do not count towards either threshold.

GOLDNBEE SIA — SAFE365 operator for the Baltics and Northern Europe · Reg. 40103558050 · VAT LV40103558050 · Jaunā Mežaparka iela 36-2, Rīga, LV-1014, Latvia

SAFE365. Ajax equipment, thoughtfully brought together.

Product information and photography on this site come from Ajax Systems. Ajax is a trademark of its owner.

Prices include standard consumer VAT for the selected country. Special tax territories, business orders, delivery, service terms and availability are confirmed with your proposal.

Loading page and saved details…