Skip to main content
Including 21% VAT · delivery terms apply

MAKE IT YOURS

FireProtect 2 (CO).

Wireless fire detector with CO sensor

MAKE IT YOURS

Wireless fire detector with CO sensor

€168.40Includes 21% VAT

Available from supplier

Residence

Choose smoke, heat, carbon monoxide or leak detection for the actual risks in each room.

Compare with another fire detector →
Colour. Black
Quantity. How many do you need?
1
Needs checking

Confirm the exact hub for FireProtect 2 RB (CO) Jeweller; family names do not identify a supported pair.

What else needs checking?

The model's general minimum is OS Malevich 2.15; identify the exact hub because host-specific limits can be higher.

Confirm the regional equipment version for LV; a country name alone does not identify the radio version.

Sensors: co. Pre-installed replaceable batteries; no separate mains supply at the detector. Indoor use at 0°C to +50°C and up to 80% humidity. Confirm placement and alarm audibility separately; this is not an EN54 system selection.

Fallback fire interconnection. Requires compatible FireProtect 2 device firmware 5.59.2.XX or later, OS Malevich 2.19+ for hub configuration, and an enabled, tested peer network. Basic hub pairing does not confirm this feature.

Required for your setup
  • A supported control panel — confirm the exact version
Ajax compatibility reference

Saved together in your project. Choose support after your equipment.

Standards and certifications

FireProtect 2 RB (CO) Jeweller · FP2.RBC.J. Manufacturer-listed marks; regional and installation conditions apply.

A dedicated warning for carbon monoxide.

FireProtect 2 (CO) Jeweller uses a chemical sensor to monitor carbon monoxide exposure and sound a local warning. A compatible Ajax hub adds device status, notifications and coordinated alarms. The RB version uses replaceable batteries. This model does not detect smoke, temperature rise, methane or other fuel gases.

Key features. At a glance.

Two types of interconnected fire alarm1

Interconnected fire alarm

Primary: via an Ajax hub, an alarm in 20 s

Replaceable batteries

RB version · two replaceable CR123A batteries

CO sensor

CO detector
Remote controlRemote control

Remote control and configuration

85 dB built-in buzzer

Jeweller radio communication

Jeweller radio communication

Power adjustment

Informative in-app notifications

10:00Ajax

Home: Carbon monoxide detected, FireProtect 2 in Kitchen

Configured photo scenario received from a compatible MotionCam (PhOD).

Up to 1,500 m2

range of communication with an Ajax hub

Operates as part of the Ajax system or without pairing with an Ajax hub

Two colours

Two coloursTwo colours
SmartbracketSmartbracket

SmartBracket

with an adjustable rotation angle

Hassle-free installation

QR-code

SmartBracket

App

  1. 1Requires supported detector hardware/firmware, hub version, configuration and tested radio coverage. See the interconnection section for the applicable conditions.
  2. 2Range is measured in open space; walls and installation conditions reduce it.

Ajax product information ↗ · FireProtect 2 RB (CO) Jeweller specifications ↗

Protection in real places.

FireProtect 2 (CO) Jeweller shown installed in a kitchen
Kitchen
FireProtect 2 (CO) Jeweller shown installed in a garage
Garage
FireProtect 2 (CO) Jeweller shown installed in a barn
Barn
FireProtect 2 (CO) Jeweller shown installed in a basement
Basement

Monitor carbon monoxide as well as exposure time.

Illustrated carbon monoxide detection; the depicted gas cloud is a visualisation

A dedicated chemical CO sensor

The sensor responds to accumulated carbon monoxide exposure. Ajax specifies an alarm within 90 minutes at 50 ppm, 40 minutes at 100 ppm and 3 minutes at 300 ppm. The CO sensor has a 10-year service life.

This is a carbon monoxide alarm, not a detector for methane or other fuel gases. It does not replace proper installation and maintenance of fuel-burning appliances.

Inside the detector.

Manufacturer animation of this FireProtect 2 enclosure and internal components

A compact detector with local controls

The enclosure brings together the sensing elements for this model, its siren, status LEDs and front-panel Test/Mute control. SmartBracket provides the mounting and tamper interface.

A local alarm, with a clear device status.

buzzer

85 dB sound and LED indications

The built-in siren is rated at 85 dB at 3 m. Sound patterns and LEDs distinguish an alarm from a fault, low battery or end of life. With a compatible connected hub, configured app notifications identify the detector and its room.

The detector monitors its own sensors even when the intrusion system is disarmed. As a standalone detector it provides local warnings; app notifications and remote settings require a hub.

Spread the alarm through the property.

Primary interconnected alarm via the hub

Primary interconnection through the hub

When an enabled detector reports an alarm, a compatible Ajax hub can activate the other fire detectors in the system within 20 seconds. The actual number of devices depends on the hub and system configuration.

Fallback interconnected alarm from detector to detector

A direct fallback between detectors

Supported FireProtect 2 RB units can also pass the alarm directly to other detectors within 60 seconds. This second path operates alongside the hub path and can continue when the hub connection is lost.

Requires detectors marked “Fallback interconnect supported”, compatible 5.59.2-series firmware, OS Malevich 2.19 or later and the fallback setting enabled. Hub (4G) requires 2.28 or later. For smoke-sensing models, use firmware 5.59.2.9 or later; check the exact detector revision before setup. Run the coverage test after setup.

Replace the batteries when needed.

Two replaceable CR123A batteries for the RB version

Two replaceable CR123A batteries

The RB version uses two pre-installed CR123A batteries, with up to 7 years of operation. Replace both batteries as instructed when a low-battery warning appears, then run the detector test.

Battery Life Optimization must be enabled for the stated lifetime; settings, radio conditions and alarm use affect it. The detector itself has a 10-year service life; new batteries do not reset it.

Connect the detector to the rest of the system.

Jeweller two-way radio

Jeweller carries alarms and device states to a compatible Ajax hub or range extender. The radio protocol uses encryption, device authentication, frequency hopping and automatic power adjustment. The specified range is up to 1,700 m in open space; walls and interference reduce it.

Check the hub and detector revision.

Model-specific compatibility

Requires OS Malevich 2.15 or later for supported hubs; Hub (4G) requires 2.28 or later. These are minimum firmware conditions, not a statement that every hub is supported. Consult the exact-model compatibility list before adding the device. Fallback interconnection has its own requirements listed above.

See which device needs attention.

Ajax app event log for this sensor combination

An event with a name and a room

When connected to a hub, the detector can report alarms and device states in the Ajax app. The event log helps identify the source and time. A monitoring service or PRO Desktop adds an operator workflow when configured and contracted.

Coordinate a response with the system.

Illustration of an electric lock used in an Ajax automation scenario

Automation needs a planned response

A compatible hub and separate Ajax automation devices can link an alarm to a professionally designed response, such as releasing a supported electric lock. The door hardware, power and evacuation requirements must be assessed together.

The detector contains no lock controller. Scenarios are additional system functions; they do not replace the required fire or CO alarm response.

Set up the detector for its actual room.

SmartBracket mounting and alignment animation

Choose and secure the position

Use the installation instructions for this sensor combination. Check the permitted room conditions, clearances and mounting position before fixing SmartBracket. Its 90° rotation adjustment helps align the enclosure after mounting.

Indoor use only: 0 to +50 °C, up to 80% humidity and IP20. A photograph of a room is an application example, not a substitute for the placement requirements.

Test it. Keep it ready.

Using the detector front panel for testing and maintenance

Test/Mute on the front panel

Press the centre of the front panel to use Test/Mute. Follow the manual to run the self-test, and confirm that the sound and light indications work. Testing is also available through the app when the detector is connected to a compatible hub.

Test after installation and battery replacement, then follow the required regular testing schedule. A self-test does not remove the need to maintain the installation.

Act on maintenance warnings

Check and respond to low-battery, fault and end-of-life indications. Keep the enclosure clean as described in the manual and replace the detector at the end of its 10-year service life.

Treat a CO alarm as an alarm.

Silencing is not an all-clear

Use remote silencing only while in the line of sight of the CO detector. The alarm cannot be muted when the CO level exceeds 300 ppm. Silencing the sound does not remove the hazard; follow the emergency instructions in the manual and your local response procedure.

Manufacturer’s product information

Find the right fire detector.

Compare what each FireProtect detects, how it is powered and what you will need to maintain. Choose the sensor combination for the hazards in the room.

Compare fire detectors →

Every detail, in one place.

Communication
Jeweller communication technology
Two-way system communication for the functions specified for this model.
Radio communication range
up to 1,700 m Between the detector and a hub (or radio signal range extender) in an open space.
Encryption of radio communication
All the data stored and transmitted are protected by block encryption with a floating key.
Radio frequency hopping
To prevent radio interference and jamming.
Carbon monoxide (CO) detection
Sensitive element
chemical CO sensor
Alarm if accumulated dose of CO is exceeded
more than 50 ppm (0.005%) — no more than in 90 minutes; more than 100 ppm (0.01%) — no more than in 40 minutes; more than 300 ppm (0.03%) — no more than in 3 minutes CO concentration of 400 ppm (0.04%) within 3 hours can be life-threatening. The detector stops notifying about the dangerous level of carbon monoxide when the concentration drops to 50 ppm (0.005%) within one minute.
Sensor life
10 years After 10 years of operation, the detector must be replaced with a new one.
Additional features
In-built siren
volume 85 dB at a distance of 3 meters Sound notification of alarms. Active until the reason for triggering is eliminated or until the user disables notification.
Interconnected fire detectors alarms
via primary interconnection If one of the fire detectors in the system detects a threat, it sends an alarm to the hub. Within 20 seconds, the hub initiates an interconnected alarm and sends data to Ajax apps. via fallback interconnection1 At the same time with notifying the hub, the initiating detector sends an alarm directly to other detectors. All connected detectors activate the buzzer within a minute. It will work even in the worst-case scenario of losing connection with the hub. 1 Fallback interconnected alarm is available only for FireProtect 2 detectors with firmware version 5.59.2.ХХ or later. Devices that support the fallback interconnected alarm are marked on the package with a “Fallback interconnect supported” label.
LED indication
green is a power indication A LED indicator on the device enclosure lights up once every 56 seconds. The indication meets the requirements of EN 50291. yellow is an indication of malfunctions A LED indicator on the device enclosure lights up when malfunctions are detected. For example, if the battery is low. red is an indication of fire alarms A LED indicator on the device enclosure lights up when the detector registers a fire alarm.
Button on the front panel of the detector
In normal mode, runs the detector test when pressed. In the event of an alarm or malfunction, the pressing turns off the detector sound notification.
Anti-sabotage protection
Tampering alarm
Alerts of attempts to detach the detector from the surface or remove the mounting panel.
Protection against spoofing
device authentication
Detection of communication failure
within 15 minutes The time to detect communication loss depends on the settings for the number of undelivered data packages (specified in the Jeweller or Jeweller/Fibra settings). The polling interval is fixed at 300 seconds.
Power supply
For FireProtect 2 RB (CO)
2 × CR123A battery Up to 7 years of battery life.
Enclosure
Dimensions
44 × 86 × 86 mm
Weight
147 g
Operating temperature range
from 0°С to +50°С
Operating humidity
up to 80%
Protection class
IP20
What’s in the box
  • FireProtect 2 RB (CO) Jeweller
  • SmartBracket mounting panel
  • Installation kit
  • 2 × CR123A battery (pre-installed)
  • Quick start guide
For your installation
  • Confirm the supported control panel, device software and regional radio version; test coverage at the final installation position.
  • The device is designed only for indoor installation. SmartBracket mounting panel allows adjusting the position of the detector after installation.
  • Choose the exact version: sensing, power, casing, pack size or interface details can differ between the listed models.

Find the right protection.

Service benefits & conditions

Eligibility, availability and service terms are confirmed with your quote.

  1. Included installation. Applies to eligible wireless equipment purchases with an agreed total from €6,000 including VAT. The proposal confirms the installation scope and local coverage. Configuration, agreed wireless installation, oversight, tests and training are included. Electrical and plumbing work and monitoring subscriptions are separate. G3 and Superior wireless S-line products do not count towards the €6,000 eligible equipment budget and are not covered by the included-installation offer. Their installation is quoted separately. Fibra and cabling are also quoted separately. Only eligible battery-powered wireless devices, ordinary hubs, ReX and wireless kits contribute. Devices requiring additional power or wired connections (including Relay, WallSwitch, LightSwitch, Socket, Outlet, FireProtect 2 AC and integration modules), WaterStop, Hub BP, video and EN54/Type4 equipment do not count. Accessories, delivery and Care fees do not count either. Hub and ReX connection to an existing socket is included; new power supplies, cabling, electrical and plumbing work are arranged separately. Included installation is available at one property in Latvia, Lithuania or Estonia and includes preparation and the visit. Below €6,000 of eligible equipment, it is a paid option at checkout. Your basket shows the complete service price, including VAT; scope and the visit date are agreed before installation.
  2. Free EU delivery. Free equipment delivery within the EU. Stock, dispatch and destination service are confirmed before accepting your order. Where a three-business-day delivery service is confirmed, it runs from dispatch. Split shipments and made-to-order products may follow separate agreed schedules. Delivery agreed as free does not acquire an undisclosed surcharge. Installation is scheduled separately.
  3. Payments, finance and leasing. Monthly payments and leasing with an upgrade option require a separate agreement, subject to finance-provider approval, credit eligibility and country availability. The provider, deposit, APR, fees, total payable, duration, ownership and return or upgrade conditions are explained before any agreement. An enquiry or saved preference does not activate credit.
  4. Personal setup. One scheduled remote first-setup session for eligible equipment purchased from SAFE365. Equipment must be ready for configuration. Session scope, language and availability are confirmed when booked; physical installation and cabling are separate unless included in your project.
  5. Care 24. Included remote support and agreed remote maintenance for the first 24 months for eligible SAFE365 purchases. The start date, support hours, access permissions and covered tasks are confirmed with your order. On-site work, 24/7 alarm monitoring and extended hardware cover are not included unless separately agreed. Statutory rights and the manufacturer's applicable warranty are unaffected.
  6. Local installation. Partner coverage varies by country and postcode. A named partner, the work scope, responsibility and price are confirmed in writing before commitment. Local installation is included only for an eligible agreed package; otherwise it is quoted separately.
  7. Included system preparation. Preparation is included from €3,000 of eligible equipment, including VAT after discounts. The order must include an eligible hub. We configure, label and check the marked wireless devices and provide individual instructions. Below the threshold, preparation is a paid option at checkout; your basket calculates the price. The same equipment eligibility rules as for included installation apply. Service charges do not count towards either threshold.

GOLDNBEE SIA — SAFE365 operator for the Baltics and Northern Europe · Reg. 40103558050 · VAT LV40103558050 · Jaunā Mežaparka iela 36-2, Rīga, LV-1014, Latvia

SAFE365. Ajax equipment, thoughtfully brought together.

Product information and photography on this site come from Ajax Systems. Ajax is a trademark of its owner.

Prices include standard consumer VAT for the selected country. Special tax territories, business orders, delivery, service terms and availability are confirmed with your proposal.

Loading page and saved details…