Skip to main content
Including 21% VAT · delivery terms apply

MAKE IT YOURS

EN54 FireProtect Jeweller detectors.

Wireless addressable point detectors

MAKE IT YOURS

Wireless addressable point detectors

€148.25Includes 21% VAT

Available from supplier

EN54

A separate professionally designed fire system. Select its control panel, detectors and alarm devices together.

Compare with another fire device →
Model. Choose the right version.
Colour. Black
Quantity. How many do you need?
1
Fire system project review

Requires a compatible EN54 fire control system. Select Smoke, Heat, Heat/Smoke, Smoke/Sounder or Heat/Sounder for the designed location; only Sounder versions include an alarm sounder.

What else needs checking?

Check the exact detector with the fire panel and its current OS Malevich version before commissioning.

Match regional radio versions and the requirements of the planned fire system.

Heat/Smoke has no built-in sounder and does not support the C-class or fixed-temperature modes of Heat and Heat/Sounder. None of these versions detects CO.

Required for your setup
  • A supported control panel — confirm the exact version
Ajax compatibility reference

Saved together in your project. Choose support after your equipment.

Standards and certifications

* Ajax shows these marks for the EN54 FireProtect Jeweller detectors range. Check the linked documentation for the exact version and market.

IP21C applies to Heat/Sounder and Smoke/Sounder. Smoke, Heat and Heat/Smoke are IP20. All five are for indoor use.

Detect the risk. Identify the location.

EN54 FireProtect Jeweller detectors bring smoke and heat detection into an addressable wireless fire system. Five versions offer smoke, heat or combined sensing, with a built-in alarm sounder on the two Sounder models. Device, room and fire-zone information helps the responsible team locate an event, while replaceable batteries simplify ongoing service.

Key features. At a glance.

Compliance1

full compliance with the fire detection and alarm system standard

bosec
sbsc
dbi

Device addressability

for informative notifications, effective management, and maintenance

Connection and configuration

via intuitive Ajax apps

Connection and configuration
Heat

Heat detection2

with selectable heat sensor mode in the app: A1, A1R, A1S, B, BR, BS, C, CR, CS, or a fixed temperature

Built-in Jeweller communication3

with the control and indicating equipment or range extender up to 1,700 m

Audible alarms4

On Heat/Sounder and Smoke/Sounder only · 32 selectable tones

Audible alarms

Smoke detection5

Patented smoke chamber with dual-spectrum sensor and HazeFlow 2 algorithm

Fast installation

5 min per device without enclosure disassembly

Fast installationFast installation

Up to 5 years6

on pre-installed CR123A batteries

Up to 5 yearsUp to 5 years

Tool-free battery replacement

without enclosure disassembly

Tool-free battery replacementTool-free battery replacement

Solo 332 compatible7

Smoke test without the need to reach the detector

Dismantling protection

with SmartBracket locking

Informative push notifications

10:00CriticalAjax

Warehouse: Smoke detected, EN54 FireProtect in zone 08, First floor, Storage

10:00CriticalAjax

Office: Rapid temperature rise detected, EN54 FireProtect in zone 03, First floor, Hall

Automatic device health check

with instant fault and service notifications

instant Notification

Tamper alarm

to alert when the device is detached or its enclosure is damaged

Two colors

of classy design to fit any interior

Two colorsTwo colors
  1. 1Manufacturer-listed marks for this product range. Exact-model certification and regional conditions are shown above.
  2. 2Heat and Heat/Sounder: EN54-compliant modes A1R, A1S, BR, BS, CR and CS. Heat/Smoke: A1R, A1S, BR and BS only; no C-class or fixed-temperature mode. Smoke-only versions have no heat sensor.
  3. 3In open space.
  4. 4Sound pressure depends on the selected tone and model; see minimum and maximum levels measured at 1 m in the exact specifications.
  5. 5Smoke sensing is included in Smoke, Smoke/Sounder and Heat/Smoke only.
  6. 6Up to 5 years for Sounder models and 6 years for Smoke, Heat and Heat/Smoke, according to the exact specifications. Actual battery life depends on use and conditions.
  7. 7For testing smoke-equipped models in the appropriate test mode; aerosol does not test a heat-only sensor.

Overview of this product range. Features and ratings can differ by version. Ajax product information ↗ · EN54 FireProtect (Heat/Sounder) Jeweller specifications ↗

Protection in real places.

EN54 FireProtect family installed in a kitchen
Kitchen
EN54 FireProtect family installed in a office
Office
EN54 FireProtect family installed in a hotel
Hotel
EN54 FireProtect family installed in a bank
Bank
EN54 FireProtect family installed in a barbershop
Barbershop
EN54 FireProtect family installed in a school
School
EN54 FireProtect family installed in a underground parking
Underground parking
EN54 FireProtect family installed in a workplace
Workplace

EN54 FireProtect Jeweller detectors

Every detail has a purpose.

Explore the function, installation and system requirements of EN54 FireProtect Jeweller detectors.

Loading detail…

Choose the detection your site needs.

Five versions. Specific functions.

Choose Smoke or Heat for one sensing type, Heat/Smoke for both, or Smoke/Sounder and Heat/Sounder to include an alarm sounder.

All five are addressable devices for a compatible EN54 fire system. None detects carbon monoxide. Heat/Smoke does not include a sounder. The family overview shows all capabilities; the selector and specifications identify the exact version.

Recognise the signs of fire.

Smoke detection

For smoke-equipped versions

A dual-spectrum optical sensor uses blue and infrared light to assess particles inside the patented smoke chamber. HazeFlow 2 evaluates the signal to help distinguish smoke from common interference.

Applies to Smoke, Smoke/Sounder and Heat/Smoke. The chamber resists dust and insects; placement and testing still follow the selected model’s manual.

Set the right heat response.

Mode follows the model and location

Heat and Heat/Sounder offer A1, A1R, A1S, B, BR, BS, C, CR, CS and a fixed-temperature mode. Heat/Smoke offers A1, A1R, A1S, B, BR and BS only.

For EN54-compliant operation use A1R, A1S, BR or BS; Heat and Heat/Sounder additionally support CR and CS. Fixed-temperature mode is not EN 54-5 compliant. The rated ambient operating range remains 0 to +50 °C.

Two sensors. A choice of response.

Only on Heat/Smoke

The combined model can use its heat and smoke sensors together or independently. The default combined mode adjusts the secondary sensor’s sensitivity as the primary sensor detects developing signs of fire.

  • Combined detection: one sensor is primary and the second helps confirm the event.
  • Heat and smoke: either sensor can trigger the alarm independently.
  • Heat only: the optical smoke sensor is not used for detection.
  • Smoke only: the heat sensor is not used for detection.

Select the detection strategy in the system design. Coincidence detection between separate detectors is a different, system-level function.

Include audible warning where it is specified.

Sounder versions only

Smoke/Sounder and Heat/Sounder include 32 selectable tones. Sounders connected to the same control panel synchronise their audible alarms. Run the alarm annunciation test to verify audibility in the actual premises.

Sound pressure depends on the selected tone and model; see the minimum and maximum levels measured at 1 m in the exact specifications. Smoke, Heat and Heat/Smoke require separately specified alarm sounders and VADs.

A supervised link to the fire panel.

Jeweller, built in

Two-way Jeweller radio carries commands, alarms and device states to the compatible fire panel. Encryption, authentication and frequency hopping protect the link without a separate radio module.

Up to 1,700 m is an open-space figure. Walls and the installation layout reduce usable range. EN54 Fire ReX can extend the route; survey each link at its final position. Alarm delivery and connection-loss timing depend on the system and its settings.

Replace the batteries. Keep the detector.

Tool-free battery replacement

Two replaceable CR123A batteries

Both batteries are pre-installed. Battery covers allow replacement without opening the detector enclosure; low-battery notifications help plan the service visit.

Up to five years for Sounder versions and up to six years for Smoke, Heat and Heat/Smoke, according to the exact specifications. Battery life depends on polling, alarms and operating conditions. Replace both batteries when notified and retest.

Know which device needs attention.

Remote system and device monitoring

Remote device states

The panel supervises communication, batteries, tamper and the sensors present in the selected detector. Events identify the device, room, fire zone and configured location.

A 36-second default polling interval is not a guaranteed fault-notification time. Check the commissioned Jeweller settings and notification routes.

Test the complete response.

Industry-standard testing support

A smoke test for smoke sensors

Smoke-equipped versions support suitable test aerosols and Solo 332 equipment in the system’s Zone test mode. Test outputs can include the chosen sounders, visual alarms, indicators and relays.

A smoke aerosol does not test a heat-only detector. Follow the exact model’s test procedure and the site’s maintenance plan. Do not remove the smoke chamber lid during routine installation.

Mount, assign and commission.

Connection

Add the exact device

Scan the QR code in an Ajax app, then assign a room, fire zone and clear location name. Use EN54 Fire Hub and the supported regional radio version.

These devices belong to the fire control system; they are not standalone domestic smoke alarms or accessories for an ordinary intrusion hub.

Manufacturer’s product information

Find the right fire device.

Compare EN54 detectors, EN54 and Type4 sounders and visual alarms, and EN54 Indicator. See what detects a fire, what warns people and what helps locate the alarm.

Compare fire detection and alarms →

Every detail, in one place.

Communication
Jeweller communication technology
Two-way system communication for the functions specified for this model.
Radio communication range
up to 1,700 m Between the device and control and indicating equipment (CIE) or a range extender in an open space.
Encrypted communication
Encrypted device communication.
Frequency hopping
To prevent radio interference and jamming.
Dangerous temperature detection
Sensitive element
2 × thermistor According to the EN 54-5 requirements for heat detectors of Class A1, B, and C with rate-of-rise (R) and static (S) response types.
Heat sensor modes
A1, A1R, A1S; B, BR, BS; C, CR, CS; Fixed temperature For better detection of fire hazards, depending on the installation site of the device. Can be selected in the device settings. Only the following heat sensor modes are compliant with EN 54 requirements: A1R, A1S, BR, BS, CR, and CS.
Alarm annunciation
Alarm type
acoustic
Sound volume
At a distance of 1 m Tone 1: 970 Hz — min 66, max 82 dB; Tone 2: 800 Hz / 970 Hz @ 2 Hz — min 66, max 86 dB; Tone 3: 800–970 Hz @ 1 Hz — min 73, max 89 dB; Tone 6: 554 Hz, 0.1 s / 440 Hz, 0.4 s — min 69, max 87 dB; Tone 7: 500–1200 Hz, 3.5 s / 0.5 s OFF — min 80, max 87 dB; Tone 13: 1200–500 Hz @ 1 Hz — min 75, max 86 dB Adjusted by a PRO or user with admin rights in an Ajax app.
Sound pattern
32 tones
Sound synchronization
An audible alarm is automatically synchronized on all devices with a sounder connected to the same CIE.
Alarm annunciation test
An audible alarm check to ensure the fire alarm is clearly audible on the premises.
Sabotage protection
Tamper button
Fault notification when an attempt is made to remove the device from the mounting panel.
Lock for SmartBracket
to secure the device on the SmartBracket mounting panel When locked, the lock secures the device and prevents it from being removed without a special tool.
Protection against spoofing
device authentication
Connection loss detection
after 36 s Detection time depends on Jeweller settings.
Power supply
Battery
2 × CR123A Pre-installed.
Tool-free battery replacement
To replace the batteries, open the lids of the battery compartments.
Reverse polarity protection
Prevents device damage if the batteries are put in incorrectly.
Recommended battery type
Huiderui CR123A; 3 V; 1,600 mAh, LiMnO₂
Calculated battery life
up to 5 years
Enclosure
Dimensions
124 × 124 × 48 mm
Weight
278 g
Operating temperature range
from 0 °C to +50 °C
Operating humidity
up to 80%
Protection class
IP21C
Flammability rating
UL 94 V-0
Revision
Revision
3
What’s in the box
  • EN54 FireProtect (Heat/Sounder) Jeweller
  • SmartBracket mounting panel
  • 2 × CR123A battery (pre-installed)
  • Installation kit
  • Quick start guide
For your installation
  • Selected as part of an installer-reviewed EN54 fire design.
  • Confirm the supported control panel, device software and regional radio version; test coverage at the final installation position.
  • The device is designed for indoor use only.
  • The SmartBracket mounting panel allows the detector to be rotated up to 90° even after installation.
  • Choose the exact version: sensing, power, casing, pack size or interface details can differ between the listed models.

Find the right protection.

Service benefits & conditions

Eligibility, availability and service terms are confirmed with your quote.

  1. Included installation. Applies to eligible wireless equipment purchases with an agreed total from €6,000 including VAT. The proposal confirms the installation scope and local coverage. Configuration, agreed wireless installation, oversight, tests and training are included. Electrical and plumbing work and monitoring subscriptions are separate. G3 and Superior wireless S-line products do not count towards the €6,000 eligible equipment budget and are not covered by the included-installation offer. Their installation is quoted separately. Fibra and cabling are also quoted separately. Only eligible battery-powered wireless devices, ordinary hubs, ReX and wireless kits contribute. Devices requiring additional power or wired connections (including Relay, WallSwitch, LightSwitch, Socket, Outlet, FireProtect 2 AC and integration modules), WaterStop, Hub BP, video and EN54/Type4 equipment do not count. Accessories, delivery and Care fees do not count either. Hub and ReX connection to an existing socket is included; new power supplies, cabling, electrical and plumbing work are arranged separately. Included installation is available at one property in Latvia, Lithuania or Estonia and includes preparation and the visit. Below €6,000 of eligible equipment, it is a paid option at checkout. Your basket shows the complete service price, including VAT; scope and the visit date are agreed before installation.
  2. Free EU delivery. Free equipment delivery within the EU. Stock, dispatch and destination service are confirmed before accepting your order. Where a three-business-day delivery service is confirmed, it runs from dispatch. Split shipments and made-to-order products may follow separate agreed schedules. Delivery agreed as free does not acquire an undisclosed surcharge. Installation is scheduled separately.
  3. Payments, finance and leasing. Monthly payments and leasing with an upgrade option require a separate agreement, subject to finance-provider approval, credit eligibility and country availability. The provider, deposit, APR, fees, total payable, duration, ownership and return or upgrade conditions are explained before any agreement. An enquiry or saved preference does not activate credit.
  4. Personal setup. One scheduled remote first-setup session for eligible equipment purchased from SAFE365. Equipment must be ready for configuration. Session scope, language and availability are confirmed when booked; physical installation and cabling are separate unless included in your project.
  5. Care 24. Included remote support and agreed remote maintenance for the first 24 months for eligible SAFE365 purchases. The start date, support hours, access permissions and covered tasks are confirmed with your order. On-site work, 24/7 alarm monitoring and extended hardware cover are not included unless separately agreed. Statutory rights and the manufacturer's applicable warranty are unaffected.
  6. Local installation. Partner coverage varies by country and postcode. A named partner, the work scope, responsibility and price are confirmed in writing before commitment. Local installation is included only for an eligible agreed package; otherwise it is quoted separately.
  7. Included system preparation. Preparation is included from €3,000 of eligible equipment, including VAT after discounts. The order must include an eligible hub. We configure, label and check the marked wireless devices and provide individual instructions. Below the threshold, preparation is a paid option at checkout; your basket calculates the price. The same equipment eligibility rules as for included installation apply. Service charges do not count towards either threshold.

GOLDNBEE SIA — SAFE365 operator for the Baltics and Northern Europe · Reg. 40103558050 · VAT LV40103558050 · Jaunā Mežaparka iela 36-2, Rīga, LV-1014, Latvia

SAFE365. Ajax equipment, thoughtfully brought together.

Product information and photography on this site come from Ajax Systems. Ajax is a trademark of its owner.

Prices include standard consumer VAT for the selected country. Special tax territories, business orders, delivery, service terms and availability are confirmed with your proposal.

Loading page and saved details…